  1.                          SECTION 09841
  2.  
  3.              FABRIC-COVERED ACOUSTICAL WALL PANELS
  4. NOTE ** This section is based on the products of the
  5.         Homasote Company, which is located at:
  6. NOTE **    P.O. Box 7240
  7. NOTE **    West Trenton, NJ  08628-0240
  8. NOTE **    Tel:  (609) 883-3300
  9. NOTE **    Fax:  (609) 530-1584
  10. NOTE **    Internet address:  http://www.homasote.com
  11. NOTE **    For local rep contact:  Sweet's Buyline 1-800-
  12.         892-1165 (#0878)
  13. NOTE ** The Homasote Company manufactures various products
  14.         for the building industry.  This section covers
  15.         only a part of their product line:
  16.         "DesignWall(tm)" and "Burlap" fabric-covered
  17.         acoustical wall panels.  DesignWall(tm) is an
  18.         elegant, prefinished interior paneling composed of
  19.         fabric laminated to structural recycled fiberboard,
  20.         available in four designer colors.
  21. NOTE **
  22. NOTE ** See their other sections for wood roof decking,
  23.         fiberboard underlayment, acoustical barriers (fire-
  24.         rated and non-rated), and cork-faced acoustical
  25.         wall panels.
  26. NOTE **
  27. NOTE ** SECTION 09841 - FABRIC-COVERED ACOUSTICAL WALL
  28.         PANELS, Copyright 1998, The Architect's Catalog,
  29.         Inc.
  30.  
  31. PART 1  GENERAL
  32.  
  33. 1.1 SECTION INCLUDES
  34. NOTE ** Select paragraphs below applicable to project.
  35.  
  36.     A.  Class A fabric-covered fiberboard panels manufactured
  37.         from recycled wood fiber material.
  38.  
  39.     B.  Class A  burlap covered fiberboard panels manufactured
  40.         from recycled wood fiber material.
  41.  
  42.     C.  Class C  burlap covered fiberboard panels manufactured
  43.         from recycled wood fiber material.
  44.  
  45. 1.2 RELATED SECTIONS
  46. NOTE ** Delete sections below not relevant to this project;
  47.         add others as required.
  48.  
  49.     A.  Section 06100 - Rough Carpentry.
  50.  
  51.     B.  Section 09110 - Non-Load-Bearing Wall Framing.
  52.  
  53.     C.  Section 09250 - Gypsum Board.
  54. NOTE ** Burlap panels can be field painted if desired.
  55.         Include specific instructions following Homasote
  56.         recommendations, in a Section on field painting.
  57.         Delete the following paragraph if painting of
  58.         burlap panels is not required.
  59.  
  60.     D.  Section _____ - Field Painting; painting of acoustic
  61.         panels.
  62.  
  63.     E.  Section _____ - _________________________.
  64.  
  65. 1.3 REFERENCES
  66. NOTE ** Delete references from the list below that are not
  67.         actually required by the text of the edited
  68.         section; add others as required.
  69.  
  70.     A.  ASTM E 84 - Test Method for Surface Burning
  71.         Characteristics of Building Materials.
  72.  
  73.     B.  AATCC 16 - Colorfastness to Light; American Association
  74.         of Textile Chemists & Colorists.
  75.  
  76.     C.  NFPA 701 - Standard Methods of Fire Tests for Flame-
  77.         Resistant Textiles and Films.
  78.  
  79.     D.  UL Test No. 214 - Standard for Tests for Flame-
  80.         Propagation of Fabrics and Films.
  81.  
  82.     E.  ____________________________________.
  83.  
  84. 1.4 SUBMITTALS
  85.  
  86.     A.  Submit under provisions of Section 01300.
  87.  
  88.     B.  Product Data:  Manufacturer's catalog data, detail
  89.         sheets, and specifications.
  90.  
  91.     C.  Samples:  Two each of manufacturer's full range of fabric
  92.         colors applied to substrate material; 7 by 7 inches (180
  93.         by 180 mm).
  94.  
  95.     D.  Quality Assurance/Control Submittals:
  96.         1.  Manufacturer's installation instructions.
  97.  
  98.     E.  Closeout Submittals:  Maintenance and cleaning
  99.         instructions.
  100.  
  101. 1.5 QUALITY ASSURANCE
  102.  
  103.     A.  Manufacturer's Qualifications:
  104.         1.  Minimum 10 years experience in producing acoustical
  105.             panels of the type specified herein.
  106.  
  107. 1.6 DELIVERY, STORAGE, AND HANDLING
  108.  
  109.     A.  Deliver materials in manufacturer's original packages.
  110.  
  111.     B.  Inspect the materials upon delivery to assure that
  112.         specified products have been received.
  113.  
  114.     C.  Report damaged material immediately to the delivering
  115.         carrier and note such damage on the carrier's freight
  116.         bill of lading.
  117.  
  118.     D.  Store materials in a dry place, indoors, or on raised
  119.         platform protected from weather damage.
  120.  
  121. 1.7 PROJECT CONDITIONS
  122.  
  123.     A.  Environmental Requirements:  For 24 hours before, during,
  124.         and continually after installation, maintain temperature
  125.         and humidity conditions that will approximate interior
  126.         conditions following building occupancy.
  127.  
  128.  
  129. PART 2  PRODUCTS
  130.  
  131. 2.1 MANUFACTURERS
  132.  
  133.     A.  Acceptable Manufacturer:  Homasote Company, P.O. Box
  134.         7240, West Trenton, NJ 08628-0240; ASD. Tel: (609) 883-
  135.         3300, Fax: (609) 530-1584, Internet address:
  136.         http://www.homasote.com; For local rep contact:  Sweet's
  137.         Buyline 1-800-892-1165 (#0878).
  138.  
  139.     B.  Requests for substitutions will be considered in
  140.         accordance with provisions of Section 01600.
  141. NOTE ** Delete paragraph above or below; coordinate with
  142.         Division 1 requirements.
  143.  
  144.     C.  Substitutions:   Not permitted.
  145.  
  146.     D.  Provide all fabric-covered acoustical wall panels from a
  147.         single manufacturer.
  148.  
  149. 2.2 MATERIALS
  150. NOTE ** Select type(s) of acoustical wall panels from the
  151.         three types below; delete those not required for
  152.         the project.
  153. NOTE **
  154. NOTE ** Nominal size of DesignWall(tm) panels is 4 by 8
  155.         feet (1.219 by 2.438 m).  DesignWall(tm) is also
  156.         available in lengths of 9, 10, and 12 feet (2.743,
  157.         3.048, and 3.657 m) on special order.  Actual size
  158.         is 1/8 inch (3 mm) less in each direction.
  159.  
  160.     A.  Class A Acoustic Panels:  Homasote DesignWall(tm)
  161.         Interior Panels.
  162.         1.  Substrate:  NCFR(R) fiberboard manufactured from 100
  163.             percent recycled wood fiber material; physical
  164.             properties as follows:
  165.             a.  Thickness:  1/2 inch (13 mm).
  166.             b.  Density:  34-40 pcf (545-640 kg/cubic m).
  167.             c.  Water Absorption by volume (2 hour immersion):  5
  168.                 percent maximum.
  169.             d.  Expansion, 50 to 90 percent relative humidity:
  170.                 0.30 percent.
  171.             e.  R-value:  0.85 (0.015).
  172.             f.  NRC:  0.20.
  173.             g.  Flame Spread:  25, per ASTM E 84.
  174.             h.  Smoke Developed:  20, per ASTM E 84.
  175.             i.  Fuel Contributed:  10.
  176.             j.  Classification:  Class A, per NFPA.
  177.         2.  Fabric:  FR 701(R), as manufactured by Guilford of
  178.             Maine, physical properties as follows:
  179.             a.  Content:  100 percent polyester.
  180.             b.  Weight:  16.0 +/- 0.5 oz./lin. yard (50 kg +/- 16
  181.                 g/m).
  182.             c.  Colorfastness to Light:  No less than Grade 4
  183.                 after 40 hours, per AATCC 16, Option A.
  184.             d.  ASTM E 84:  Class A.
  185.             e.  NFPA-701:  Passes.
  186.             f.  UL Test No. 214:  Passes.
  187. NOTE ** Delete the following agencies not applicable to the
  188.         project.
  189.             g.  FAA (PARA.25.853B):  Passes.
  190.             h.  NY/NJ Port Authority (FTMS 191-5903):  Passes.
  191.             i.  Boston Fire Code BFD IX-1:  Passes.
  192.             j.  State of Massachusetts 527 CMR 21.00:  Passes.
  193.             k.  State of California Tech Bulletin 117 Section E
  194.                 (CS-191-53):  Passes.
  195.             l.  GSA-PBS:  Passes.
  196. NOTE ** Select color(s) from the following subparagraphs,
  197.         deleting those not applicable to the project.
  198.             m.  Color:  380 Quartz.
  199.             n.  Color:  400 Cherry Neutral.
  200.             o.  Color:  401 Blue Neutral.
  201.             p.  Color:  238 Grey Mix.
  202.             q.  Color:  As selected by Architect from
  203.                 manufacturer's standard range.
  204.         3.  Fabrication:  Wrap fabric around long edges of panel
  205.             to back side and laminate to substrate.
  206. NOTE ** Nominal size of Burlap panels is 4 by 8 feet (1.219
  207.         by 2.438 m).  Burlap Panels are also available in
  208.         lengths of 10 and 12 feet (3.048 and 3.657 m) on
  209.         special order.  Actual size is 1/8 inch (3 mm) less
  210.         in each direction.
  211.  
  212.     B.  Class C Acoustic Panels:  Homasote Burlap Panels.
  213.         1.  Substrate:  "440" fiberboard manufactured from 100
  214.             percent recycled wood fiber material; physical
  215.             properties as follows:
  216.             a.  Thickness:  1/2 inch (13 mm).
  217.             b.  Density:  24-26 pcf (385-415 kg/cubic m).
  218.             c.  Water Absorption by volume (2 hour immersion):  5
  219.                 percent maximum.
  220.             d.  Expansion, 50 to 90 percent relative humidity:
  221.                 0.25 percent.
  222.             e.  R-value:  1.11 (0.19).
  223.             f.  NRC:  0.20.
  224.             g.  Flame Spread:  Less than 200, per ASTM E 84.
  225.             h.  Classification:  Class C, per NFPA.
  226.         2.  Burlap:  Natural colored heavyweight jute fabric.
  227.         3.  Fabrication:  Wrap fabric around long edges of panel
  228.             to back side and laminate to substrate.
  229. NOTE ** Class A Burlap Panels as follows are available on
  230.         special order.  They are qualified for use in
  231.         educational, institutional, museum, or publicly
  232.         attended facility -- whereever a Class A Fire
  233.         Hazard rating is required.
  234.  
  235.     C.  Class A Fire-Rated Acoustic Panels:  Homasote Fire
  236.         Resistant Burlap Panels.
  237.         1.  Substrate:  NCFR(R) fiberboard manufactured from 100
  238.             percent recycled wood fiber material; physical
  239.             properties as follows:
  240.             a.  Thickness:  1/2 inch (13 mm).
  241.             b.  Density:  34-40 pcf (545-640 kg/cubic m).
  242.             c.  Water Absorption by volume (2 hour immersion):  5
  243.                 percent maximum.
  244.             d.  Expansion, 50 to 90 percent relative humidity:
  245.                 0.30 percent.
  246.             e.  R-value:  0.85 (0.015).
  247.             f.  NRC:  0.20.
  248.             g.  Flame Spread:  25, per ASTM E 84.
  249.             h.  Smoke Developed:  20, per ASTM E 84.
  250.             i.  Fuel Contributed:  0.
  251.             j.  Classification:  Class A, per NFPA.
  252.         2.  Burlap:  Natural colored tight-weave fabric,
  253.             chemically treated to resist fire.
  254.         3.  Fabrication:  Wrap fabric around long edges of panel
  255.             to back side and laminate to substrate.
  256.         4.  Panel Fire Resistance:
  257.             a.  Flame Spread:  20, Class A, per ASTM E 84.
  258.             b.  Smoke Developed:  0, Class A, per ASTM E 84.
  259.             c.  Fuel Contributed:  10.
  260.             d.  Classification:  Class A, per NFPA.
  261.  
  262. 2.3 ACCESSORIES
  263. NOTE ** Installation accessories are dependent on
  264.         substrates and installation methods as recommended
  265.         by the manufacturer; select from the following
  266.         paragraphs accordingly.
  267. NOTE **
  268. NOTE ** Homasote joint and trim moldings in low lustre
  269.         black or white are also available, including cap,
  270.         inside and outside corners, and "H" for butt
  271.         joints.  Inquire of the manufacturer.
  272.  
  273.     A.  Metal Frame Clips:  Manufacturer's standard clip for
  274.         securing panels to framing.
  275.  
  276.     B.  Adhesive:  APA approved panel adhesive.
  277.  
  278.     C.  Adhesive:  APA AFG-01 subfloor adhesive.
  279.  
  280.     D.  Nails:  Color coordinated paneling nails, length as
  281.         required to penetrate wood framing 3/4 inch (19 mm)
  282.         minimum.
  283.  
  284.     E.  Nails:  Finishing nails, length as required to penetrate
  285.         wood framing 3/4 inch (19 mm) minimum.
  286.  
  287.     F.  Screws:
  288.         1.  Wood Framing:  Coarse thread drywall type wood screw,
  289.             length as required to penetrate framing 3/4 inch (19
  290.             mm) minimum.
  291.         2.  Metal Framing:  22-25 gage, drywall type steel screw.
  292.         3.  Metal Framing:  20 gage or heavier, self-tapping
  293.             drywall type steel screw.
  294.  
  295.  
  296. PART 3  EXECUTION
  297.  
  298. 3.1 EXAMINATION
  299.  
  300.     A.  Examine substrates upon which work will be installed.
  301.  
  302.     B.  Verify framing member spacing complies with
  303.         manufacturer's requirements depending on substrates and
  304.         installation methods.
  305.  
  306.     C.  Verify environmental conditions are, and will continue to
  307.         be, maintained in accordance with manufacturer's
  308.         recommendations.
  309.  
  310.     D.  Coordinate with responsible entity to perform corrective
  311.         work on unsatisfactory substrates or conditions.
  312.  
  313.     E.  Starting work by installer is acceptance of substrate and
  314.         environmental conditions.
  315.  
  316. 3.2 PREPARATION
  317.  
  318.     A.  Follow manufacturer's instructions for allowing panels to
  319.         be exposed to environmental temperature and humidity
  320.         conditions for not less than 24 hours before start of
  321.         installation.
  322. NOTE ** Burlap is a natural fabric and can vary in shade
  323.         between production runs.  Before installation,
  324.         Burlap Panels should be positioned in place to
  325.         ensure that desired appearance is obtained.  Delete
  326.         the following paragraph if Burlap Panels are not
  327.         specified.
  328.  
  329.     B.  Temporarily position Burlap Panels in place and request
  330.         Architect's approval, to ensure that desired appearance
  331.         is obtained.
  332.  
  333. 3.3 INSTALLATION
  334. NOTE ** Homasote specifies framing at 16 inches (400 mm)
  335.         o.c. for all installation methods except over
  336.         finished walls; panel edges and ends are required
  337.         to align with framing members or be blocked for all
  338.         methods.  Verify that appropriate framing section
  339.         or drawing notes comply.  Special framing may be
  340.         required if panel joint layout is defined.
  341. NOTE **
  342. NOTE ** Furring for masonry or concrete walls can be one-
  343.         by's (19 mm) wood or standard hat-shaped metal
  344.         furring channels.  Specify furring in the
  345.         appropriate wood or metal framing section.
  346.  
  347.     A.  Follow manufacturer's instructions for cutting and
  348.         installation of panels:
  349. NOTE ** Installation is dependent on substrates; select
  350.         from the following subparagraphs accordingly,
  351.         deleting those not required for the project.
  352.         1.  Wood Framed Walls, Method No. 1, (using framing
  353.             clips).
  354.         2.  Wood Framed Walls, Method No. 2, (using adhesive).
  355.         3.  Metal Framed Walls.
  356.         4.  Wood or Metal Furring over masonry or concrete walls.
  357.         5.  Finished Walls (walls with continuous substrate in
  358.             place).
  359.  
  360. 3.4 CLEANING
  361.  
  362.     A.  Follow manufacturer's instructions for cleaning panels
  363.         soiled during installation.
  364.  
  365.     B.  Replace panels that cannot be cleaned to "as new"
  366.         condition.
  367.  